info@awind-cn.com    +86-769-89386135
Cont

Have any Questions?

+86-769-89386135

Extrusion Profile Liquid Cold Plate Copper Tube Al Heatsink for LED Bulbs

Extrusion Profile Liquid Cold Plate Copper Tube Al Heatsink for LED Bulbs

In this experiment, we will use copper tube water cooling plate to conduct a thermal simulation of 1200w led. Through the temperature graph, pressure graph, Velocity Vector, etc, you can better see the effect of the water cooling plate in terms of heat dissipation. The experiment will provide two solution.
Send Inquiry

Product Introduction

We insist on the quality of our AL Extrusion Heat Sink, Friction Stir Welding Liquid Cold Plate, Cold Forged Heat Sink and sincere services to gain the recognition of users and continuously improve the credibility, reputation and popularity of our brand. Relying on the rich experience accumulated over the years and the professional knowledge of excellence, we adopt advanced management concepts, carry out strict quality management, and provide high-quality service to customers. In the continuous development, we demand ourselves with the highest goal, constantly improve our own management mode, and improve the ability and level of customer service. We will strive to meet the many needs of our customers for safety, reasonableness, and high quality. Our entrepreneurial spirit is "Quality first, customer first, determined to innovate, and pursue perfection".


Thermal Simulation of Water Cooling Plate with Copper Pipe

In this experiment, we will use water cooling plate with copper pipe to conduct a thermal simulation of 1200w led. 

Through the temperature graph, pressure graph, Velocity Vector, etc, you can better see the effect of the water cooling plate with copper pipe in terms of heat dissipation. The experiment will provide two solution.



Design Input

Cooling method: Forced water cooling

Coolant: Pure water

Ambient temp. Ta: 40℃

LED watt loss: 1114W

Max temp: 50-60℃


1


Design parameter

1. Ambient temp. Ta [°C]: 40C

2. Cabinet temp. Tw [°C]: Unit will be on the top (outside) the cabinet only the glass side will be in the cabinet

3. Cabinet dimension: Unit will be outside the cabinet

4. Power dissipated P[W]: Total Electrical installed power 1500Watt but dissipated around 1200Watt

5. Heat source quantity: Check attached pictures

6. Heat source position and dimension: Check Attached pictures

7. Location of in/outlet water (better to provide system 3D file): Check Attached pictures

8. Accept Max Temp on cold plate [°C]: 50 till 60

9. Installation Hole dimension and position of cold plate: Check the pictures, I have now only 4 holes drawed for assembly the unit the unit till the cabinet. I need a lot of holes for assembly the LED PCB's and Channel Driver and PSU. I want to place alu baseplates to drill all the holes to mount the baseplates I need only a view holes with thread.

10. Liquild Flow rate: _____L/min Depends on what the thermal analysis will tell us what the flow rate must be.

11. Liquid cooling plate Max.size: See Pictures size will be 680x600 but the actual colling area will be 600x540

12. Liquid type: Pure water

13. Temperature of inlet water: Depends on the result of the thermal analysis

14. Temperature of outlet water: Depends on the result of the thermal analysis.

15. Allow Max. pressure of cold plate: Depends on the result of the thermal analysis.


3

4

The model of coolant




5




Solution 1: Velocity of Inlet=0.5m/s(2.7L/min)


6

Temperature of Cool Plate



7

Pressure Drop:5842.6Pa



8

Temperature of Coolant



9(001)

Velocity Vector



Solution 2: Velocity of Inlet=0.3m/s(1.62L/min)


10

Temperature of Cool Plate



11

Pressure Drop:2898.7Pa



12

Temperature of Coolant



13(001)

Velocity Vector


Conclusion

Flow(L/min)

Tmax (0C)

DeltaT (0C)

Delta P (Pa)

Resistance( 0C/W)

2.7L/min

46.817

6.817

5842.6

0.00612

1.62L/min

50.838

10.838

2898.7

0.00973


With this design( Al Cool Plate ), the simulation result of solution meet the Spec.


Our excellent Extrusion Profile Liquid Cold Plate Copper Tube Al Heatsink for LED Bulbs quality and timely service for the enterprise has won a good reputation. Our reputation comes from the rock-like quality of our products! In terms of material selection, we strictly control the quality; in the finished product inspection link, we strictly carry out the withstand voltage test in accordance with the relevant national standards, so that unqualified products are not delivered for use. We effectively stimulate the subjective initiative and creativity of employees through the value-oriented system with the assessment standard of responsibility and contribution, so as to realize the harmonious unity of employee value and enterprise value.

Hot Tags: Thermal Simulation of Water Cooling Plate with Copper Pipe, China, suppliers, manufacturers, factory, customized, free sample, made in China, Ultra Thin Vapor Chamber Heatsink, CPU Heat Sink Design, Bonded Heat Sink, AL Extrusion Heat Sink, Heat Pipe Heat Sink, Vacuum Brazing Liquid Cold Plate

[[ProKeywords]]

Send Inquiry