We abide by the core values of respecting rules, innovation and pragmatism, and provide the best quality Liquid Cold Plate, Water Cooling Plate with Copper Pipe, Copper Skived Heat Sink for our customers. The company has always been adhering to the quality policy of "Quality First, Customer First, Service Quality, Continuous Improvement", and has made unremitting efforts for the organizational vision of "leading the industry's technological innovation, meeting customers' individual high-end needs, and building an environmentally friendly enterprise". Enterprises must establish a mechanism to cultivate dedication and innovation, and build a platform for employees to better develop their talents. The harmonious unification of the two is an effective way to greatly stimulate and tap the potential of employees. Continuously strengthen the trust and support between partners and promote win-win cooperation is our unchanging original intention.
Liquid cooling plate
Principle of liquid cooling: In a closed liquid circulation device, the liquid is flowed by the pump. During the liquid flowing on the heat source, the heat was taken by the liquid. Finally, the liquid is returned to the pump and circulate again and again.
Due to high cooling performance, the thermal conductivity is 20 times than air cooling, can solve hundreds or thousands of KW heat problems. Wildly used in Laser, Military, Medical, Power electronic, Industrial equipment and etc.
Liquid cooling plate design case
Design input
Required cooling capacity per plate: 1.6kW
Supply/Return water temperature: 8/13 deg.C
Plate surface temperature: 20 deg.C
Max. Surface temperature: 40 deg.C
Ambient temperature: 24 deg.C to 26 deg.C
Max. Size of cold plate: 940mm(L) x 145mm(W)
Maximum thickness of plate: 15mm
DN of copper tube: 9.5mm with 7.1mm I.D.
Water flow velocity: 2.5m/s (max)
Number of holes: 14 (M6 x 25mm countersunk screws as shown below in red and blue)
Heat source

Thermal Simulation
Solution: liquid cold plate
Liquid cold plate base size: 940*145*12.7mm, material: AL6061
Copper tube size: diameter 9.5mm, thickness=1.27mm, material: C1100

Simulation model (ICEPAK)

Pressure Drop: 1632Pa

Max Velocity: 1.97m/s

Heat sink Temperature
△T: 10.6044℃
Conclusion
Type | Ta(℃) | Tb-max(℃) | Delta T | Flow | Resistance(℃/W) |
AL extrusion | 25.0 | 35.6044 | 10.6044 | 1.97m/s | 0.0066 |
Ta: Environment temperature
With this design, the simulation result of solution can meet your requirements.
Drawing design


Epoxy bonding
Epoxy features:
• Excellent Thermal Conductivity
• Superior Adhesion
• Low Viscosity allows quick self leveling
Process


Main points
Solution temperature:50+/5℃ Soak around 3 min
Liquid PH: 6~8

Solution pond

Soak around 3 min
Stoppers to avert chemical solution getting into the tube

Apply 70-3812 high thermal epoxy, measure the weight: after applying - before applying=0.2 +/-1g


Apply Epoxy again for better bonding result, measure by weight: after applied- before applied=1~3g fill up all cavities formed after stamping.

Auto dispenser to apply Epoxy

Fill up all cavities formed after stamping
Fly cut for better flatness
Overall surface:<0.1mm for 100x100mm area
Heat source contact surface:<0.05mm for 100x100mm area

Ultrasonic cleaning again for cosmetic purpose
IR sensor to monitor welding temperature.
Welding power: connector 1410+/- 10w
Pipe: 1200 +/- 10w

Position sensor to the welding joint
Sensor temperature:
Connector: 200~650
Pipe: 200~580
Time for the welding object to reach constant temperature: 2.5min

HF induction welding machine
Quality inspection test
Our liquid cooled plates will be inspected before delivery to customers to ensure the quality of the products. We will ensure the quality of our products through leak testing and pressure testing.
Leak testing 1:High pressure N2 to check possible leakage

Hook on USON tester

Supply N2 to USON at 150+/-1 PSI
Hold for 5min
Criterion: pressure drop <= 1%
If fails, use He tester to locate leakage points
Leak testing 2: Sort out leakage location by high sensitivity He

He tester
Supply He to tester at 25+/- 1 PSI
Criterion: leakage<9.9*10-5Mbar.I/s

Sniffer to detect
Mark leakage area in red if any
Pressure testing: Low pressure N2 to check possible leakage

Hook on USON tester

Auto detection/ judgement per requirement
Supply N2 to USON at 30+/-1 PSI
Hold for 24 hours
Criterion: pressure drop <=5%
If fails, use He tester to locate leakage point
We firmly establish the concept of superb technology and exquisite quality, aiming at high standards and pursuing high levels of EV Battery Aluminium Cooling Plate Liquid Cooling Plate. Team concept is the guideline and value proposition for the company to strengthen the team construction and enhance the team ability. With the unremitting efforts of our scientific researchers, we have made one new scientific and technological breakthrough after another.
Hot Tags: liquid cooling plate, China, suppliers, manufacturers, factory, customized, free sample, made in China, Water Cooling Plate with Copper Pipe, Anodized Heatsink, Bonded Fin Heat Sinks Assemblies, Heatsink Design, Industrial Water Cooling Cold Plate, Ultra Thin Vapor Chamber Heatsink
[[ProKeywords]]