In this experiment, we will use copper tube water cooling plate to conduct a thermal simulation of 1200w led. Through the temperature graph, pressure graph, Velocity Vector, etc, you can better see the effect of the water cooling plate in terms of heat dissipation. The experiment will provide two solution.
Send Inquiry

Product Introduction

We have unswervingly flattered the idea of ??making Cold Forged Heat Sink, Folded Fin Heat Sink, CPU Heat Sink Design with heart, and are committed to becoming your reliable long-term partner. The company’s leaders have always been committed to the training of employees’ ideology, technical skills, and cultural qualities to create a high-quality workforce and continue to promote the development of the company. We have established a product development team and a modern management platform to keep pace with the times. We are looking forward to a fair and reasonable settlement through consultation, adhering to quality and service and sincere cooperation, so that we have made achievements and won a reputation. The market is the foundation of enterprise development, and credibility is the guarantee for the survival of the enterprise. We work hand in hand with friends from all over the world who are in the same boat through storms and hardships, gather the wisdom of the team and the spirit of struggle, build a brand, keep pace with the times, and share extraordinary quality with you.


Thermal Simulation of Water Cooling Plate with Copper Pipe

In this experiment, we will use water cooling plate with copper pipe to conduct a thermal simulation of 1200w led. 

Through the temperature graph, pressure graph, Velocity Vector, etc, you can better see the effect of the water cooling plate with copper pipe in terms of heat dissipation. The experiment will provide two solution.



Design Input

Cooling method: Forced water cooling

Coolant: Pure water

Ambient temp. Ta: 40℃

LED watt loss: 1114W

Max temp: 50-60℃


1


Design parameter

1. Ambient temp. Ta [°C]: 40C

2. Cabinet temp. Tw [°C]: Unit will be on the top (outside) the cabinet only the glass side will be in the cabinet

3. Cabinet dimension: Unit will be outside the cabinet

4. Power dissipated P[W]: Total Electrical installed power 1500Watt but dissipated around 1200Watt

5. Heat source quantity: Check attached pictures

6. Heat source position and dimension: Check Attached pictures

7. Location of in/outlet water (better to provide system 3D file): Check Attached pictures

8. Accept Max Temp on cold plate [°C]: 50 till 60

9. Installation Hole dimension and position of cold plate: Check the pictures, I have now only 4 holes drawed for assembly the unit the unit till the cabinet. I need a lot of holes for assembly the LED PCB's and Channel Driver and PSU. I want to place alu baseplates to drill all the holes to mount the baseplates I need only a view holes with thread.

10. Liquild Flow rate: _____L/min Depends on what the thermal analysis will tell us what the flow rate must be.

11. Liquid cooling plate Max.size: See Pictures size will be 680x600 but the actual colling area will be 600x540

12. Liquid type: Pure water

13. Temperature of inlet water: Depends on the result of the thermal analysis

14. Temperature of outlet water: Depends on the result of the thermal analysis.

15. Allow Max. pressure of cold plate: Depends on the result of the thermal analysis.


3

4

The model of coolant




5




Solution 1: Velocity of Inlet=0.5m/s(2.7L/min)


6

Temperature of Cool Plate



7

Pressure Drop:5842.6Pa



8

Temperature of Coolant



9(001)

Velocity Vector



Solution 2: Velocity of Inlet=0.3m/s(1.62L/min)


10

Temperature of Cool Plate



11

Pressure Drop:2898.7Pa



12

Temperature of Coolant



13(001)

Velocity Vector


Conclusion

Flow(L/min)

Tmax (0C)

DeltaT (0C)

Delta P (Pa)

Resistance( 0C/W)

2.7L/min

46.817

6.817

5842.6

0.00612

1.62L/min

50.838

10.838

2898.7

0.00973


With this design( Al Cool Plate ), the simulation result of solution meet the Spec.


As always, we will sell the best cost-effective Battery Packs Customized Copper Tube Liquid Cold Cooling Plate Heat Exchange Cold Plate with the best quality, and offer the most attentive service to you. We adhere to the 'quality credibility, innovation and development' as the business policy and 'hard work, integrity' as the business principle. We hope that in an innovative corporate culture, each employee's ability can be improved within the company.

Hot Tags: Thermal Simulation of Water Cooling Plate with Copper Pipe, China, suppliers, manufacturers, factory, customized, free sample, made in China, High Quality Heat Sink, Vapor Chamber Heatsink, CPU Heat Sink Design, Aluminum Extruded Heatsink for Motor, Vacuum Brazed Liquid CooLED Plates, FSW Liquid Cooling Plate