Our personnel are generally within the spirit of 'continuous improvement and excellence', and using the excellent top quality goods, favorable rate and superior after-sales expert services, we try to win every customer's believe in for Friction Stir Welding Liquid Cold Plate, Round Aluminum Heatsink for LED, Aluminum Cold Plates for Battery. Our people-oriented management concept attracts a large number of professionals and management talents. We aim to create to meet customer needs, innovate to seek enterprise development, and start business to achieve industrial upgrading.
Thermal Simulation of Water Cooling Plate with Copper Pipe
In this experiment, we will use water cooling plate with copper pipe to conduct a thermal simulation of 1200w led.
Through the temperature graph, pressure graph, Velocity Vector, etc, you can better see the effect of the water cooling plate with copper pipe in terms of heat dissipation. The experiment will provide two solution.
Design Input
Cooling method: Forced water cooling
Coolant: Pure water
Ambient temp. Ta: 40℃
LED watt loss: 1114W
Max temp: 50-60℃

Design parameter
1. Ambient temp. Ta [°C]: 40C
2. Cabinet temp. Tw [°C]: Unit will be on the top (outside) the cabinet only the glass side will be in the cabinet
3. Cabinet dimension: Unit will be outside the cabinet
4. Power dissipated P[W]: Total Electrical installed power 1500Watt but dissipated around 1200Watt
5. Heat source quantity: Check attached pictures
6. Heat source position and dimension: Check Attached pictures
7. Location of in/outlet water (better to provide system 3D file): Check Attached pictures
8. Accept Max Temp on cold plate [°C]: 50 till 60
9. Installation Hole dimension and position of cold plate: Check the pictures, I have now only 4 holes drawed for assembly the unit the unit till the cabinet. I need a lot of holes for assembly the LED PCB's and Channel Driver and PSU. I want to place alu baseplates to drill all the holes to mount the baseplates I need only a view holes with thread.
10. Liquild Flow rate: _____L/min Depends on what the thermal analysis will tell us what the flow rate must be.
11. Liquid cooling plate Max.size: See Pictures size will be 680x600 but the actual colling area will be 600x540
12. Liquid type: Pure water
13. Temperature of inlet water: Depends on the result of the thermal analysis
14. Temperature of outlet water: Depends on the result of the thermal analysis.
15. Allow Max. pressure of cold plate: Depends on the result of the thermal analysis.


The model of coolant

Solution 1: Velocity of Inlet=0.5m/s(2.7L/min)

Temperature of Cool Plate

Pressure Drop:5842.6Pa

Temperature of Coolant

Velocity Vector
Solution 2: Velocity of Inlet=0.3m/s(1.62L/min)

Temperature of Cool Plate

Pressure Drop:2898.7Pa

Temperature of Coolant

Velocity Vector
Conclusion
Flow(L/min) | Tmax (0C) | DeltaT (0C) | Delta P (Pa) | Resistance( 0C/W) |
2.7L/min | 46.817 | 6.817 | 5842.6 | 0.00612 |
1.62L/min | 50.838 | 10.838 | 2898.7 | 0.00973 |
With this design( Al Cool Plate ), the simulation result of solution meet the Spec.
We are committed to repaying society with the best 3015 Metal Tube Pipe and Plate Fiber Laser Cutting Machine on Sale with Good Price and services, giving full play to our traditional advantages and optimizing our industrial layout. We are speeding up the pace of production, operation, reform and development of enterprises in an all-round way. We hope to join the ranks of advanced enterprises through hard work. We have a perfect after-sales service mechanism, and we always adhere to the spirit of service with a smile concept and sincere rational attitude to communicate with each customer.
Hot Tags: Thermal Simulation of Water Cooling Plate with Copper Pipe, China, suppliers, manufacturers, factory, customized, free sample, made in China, High Quality Heat Sink, Water Cooling Plate with Copper Pipe, Vacuum Brazing Liquid Cold Plate, Liquid Cold Plate for Power Supply, Cooling Plate Heat Sinks, Vacuum Brazing Liquid Cooling Heatsink