Our company has strong technical force and strong R & D ability, pays attention to the production quality of products, pays attention to the needs of customers and the market trends, and focuses on the development and development of new Vapor Chamber Heat Sink, Liquid Cold Plate for Power Supply, Cold Forging Heat Sink for LED. We hope that every employee should rely on their own efforts and talents to strive for the opportunities provided by the company. Fierce market competition requires our company to quickly respond to changes in market demand, and even the ability to guide market demand.
Thermal Simulation of Water Cooling Plate with Copper Pipe
In this experiment, we will use water cooling plate with copper pipe to conduct a thermal simulation of 1200w led.
Through the temperature graph, pressure graph, Velocity Vector, etc, you can better see the effect of the water cooling plate with copper pipe in terms of heat dissipation. The experiment will provide two solution.
Design Input
Cooling method: Forced water cooling
Coolant: Pure water
Ambient temp. Ta: 40℃
LED watt loss: 1114W
Max temp: 50-60℃

Design parameter
1. Ambient temp. Ta [°C]: 40C
2. Cabinet temp. Tw [°C]: Unit will be on the top (outside) the cabinet only the glass side will be in the cabinet
3. Cabinet dimension: Unit will be outside the cabinet
4. Power dissipated P[W]: Total Electrical installed power 1500Watt but dissipated around 1200Watt
5. Heat source quantity: Check attached pictures
6. Heat source position and dimension: Check Attached pictures
7. Location of in/outlet water (better to provide system 3D file): Check Attached pictures
8. Accept Max Temp on cold plate [°C]: 50 till 60
9. Installation Hole dimension and position of cold plate: Check the pictures, I have now only 4 holes drawed for assembly the unit the unit till the cabinet. I need a lot of holes for assembly the LED PCB's and Channel Driver and PSU. I want to place alu baseplates to drill all the holes to mount the baseplates I need only a view holes with thread.
10. Liquild Flow rate: _____L/min Depends on what the thermal analysis will tell us what the flow rate must be.
11. Liquid cooling plate Max.size: See Pictures size will be 680x600 but the actual colling area will be 600x540
12. Liquid type: Pure water
13. Temperature of inlet water: Depends on the result of the thermal analysis
14. Temperature of outlet water: Depends on the result of the thermal analysis.
15. Allow Max. pressure of cold plate: Depends on the result of the thermal analysis.


The model of coolant

Solution 1: Velocity of Inlet=0.5m/s(2.7L/min)

Temperature of Cool Plate

Pressure Drop:5842.6Pa

Temperature of Coolant

Velocity Vector
Solution 2: Velocity of Inlet=0.3m/s(1.62L/min)

Temperature of Cool Plate

Pressure Drop:2898.7Pa

Temperature of Coolant

Velocity Vector
Conclusion
Flow(L/min) | Tmax (0C) | DeltaT (0C) | Delta P (Pa) | Resistance( 0C/W) |
2.7L/min | 46.817 | 6.817 | 5842.6 | 0.00612 |
1.62L/min | 50.838 | 10.838 | 2898.7 | 0.00973 |
With this design( Al Cool Plate ), the simulation result of solution meet the Spec.
We rely on technological progress, strict management, and perfect services to provide customers with quality 2021 Laser Steel Cutting Dual Use for Metal Sheet Plate and Tube Pipe Cutting Machine for Sale. A modern enterprise that gathers elite talents and establishes a technical base is our goal and the development path that the company is taking. Our goal is to achieve the company's strategic goals, enhance the external competitiveness of enterprises and improve the efficiency of business operations.
Hot Tags: Thermal Simulation of Water Cooling Plate with Copper Pipe, China, suppliers, manufacturers, factory, customized, free sample, made in China, Bonded Fin Heat Sinks Assemblies, Anodized Heatsink, Liquid Cold Plate for Power Supply, Vc Heat Sink, Ultra Thin Vapor Chamber Heatsink, Round Aluminum Heatsink for LED